Q&A Forum

Jostein
@admin
Admin
Member
Topics: 26 / Replies: 1419
Reply
RE: Yourdyno v5 installation onto a Dynojet 200i Questions about ignition rpm & lambda

Yes, try the Dynojet pickup. If it is an inductive pickup then it is a good chance it will work. Best to clip over the primary (12V) of the coil, not ...

1 year ago
Reply
RE: Yourdyno v5 installation onto a Dynojet 200i Questions about ignition rpm & lambda

Hi, With a new YourDyno Standard (the v5) you don't need the MSD tach pickup. You just need an inductive pickup like this for example. If you rath...

1 year ago
Reply
RE: Latest software version

@boz-race-engines, Yes, all blue boxes. You must upgrade the firmware by clicking the Upgrade to latest button.

1 year ago
Reply
RE: Latest software version

All right, folks! The new YourDyno software version is finally available, version 3.3.50. It is a big release with lots of new features and improve...

1 year ago
Reply
RE: DTEC RPM Adapter

Use RPM2 and set it as "Other RPM channel" in the RPM/Frequency channel setup. Call it something like RPM Pickup or DTEC RPM or something like that. ...

1 year ago
Reply
RE: load arm length effect

Generally shorter arm is better because it picks up less vibrations. Apart from that, you the arm impacts the load on the load cell, so choose a combi...

1 year ago
Reply
RE: Engine rpm same as RPM1

Hi, This can be confusing, but the Engine RPM is equal to roller RPM * Gear ratio. This is the main RPM that the system is using to calculate engin...

1 year ago
Reply
RE: Power sweep won’t hit 12k rpm

Good video. The brake regulation is good but a little nervous until about 10.5k RPM, then it starts oscillating. Check Kp, Ki and Kd vs Time to see...

1 year ago
Reply
RE: Froude G490EH conversion

That's a proper analog setup 🙂 !

1 year ago
Reply
RE: Latest software version

@matteozanusso, thanks if you can send your options file to me and I can try to reproduce that crash. Go to this folder location: %localappdata%\Fonne...

1 year ago
Reply
RE: Install software issue

For everyone's information, it was an anti virus issue. Norton Antivirus had flagged the file.

1 year ago
Reply
RE: Install software issue

Get in touch at jostein@yourdyno.com or call me at +47 4840 1279. Install Ultraviewer. I will login and take a look.

1 year ago
Reply
RE: Install software issue

Does it say a reason why it cannot run? Windows 10 is supported. What CPU do you have (Right click on "This PC" and click Properties).

1 year ago
Reply
RE: Simulated hardware for plugins dev/debug

Maybe something like this works? Network Serial Port Kit - share and access COM port over Ethernet (network-serial-port.com)

1 year ago