Jostein
@admin
Admin
Member
Topics: 26 / Replies: 1419
Reply
RE: xencelabs Remote INOP

Hi, You need to define the Hotkeys in the Options menu, did you do that?

3 years ago
Reply
RE: Latest software version

@matteozanuss, great to hear.

3 years ago
Reply
RE: RPM trigger wheel

@furntrattrene, The reason for the difference in RPM is most likely that the tires compress under load, so their effective diameter decreases. So th...

3 years ago
Reply
RE: Latest software version

Hi, Seems there was a library issue in version 3.2.137. Here is version 3.2.138. Cheers

3 years ago
Reply
RE: Dyno module not working after one day

Hi, you sent me a mail about this and I send two replies but it seems you did not get them. Open the unit, press the button while connected to the ...

3 years ago
Reply
RE: RPM trigger wheel

When a dyno is in inertia mode, it still matters where the trigger wheel is placed. But it only matters in terms of the effective MOI. Move the trigge...

3 years ago
Reply
RE: Latest software version

@breastfed, I have not seen that problem. Maybe a reboot does the trick? Or try to uninstall the previous version first. @six_shooter, 137 is the la...

3 years ago
Reply
RE: Rewiring a retarder

Thanks, this is useful info when rewiring from 96V to 192V. For rewiring from 24V to 192V, here is a picture.  rewire-telma.JPG

3 years ago
Reply
RE: RPM trigger wheel

Hello, Apologies, I missed your message. The trigger wheel shall be on the same axle as the brake. If this is not possible, then you need to calc...

3 years ago
Reply
RE: Latest software version

Tuners, A very minor bug fix, in that the OBD2 RPM had dropped out of the Engine RPM source in Gear Ratio setup. Fixed here: YourDynoInstaller_3....

3 years ago
Reply
RE: Latest software version

@dev, on the total correction formula. The confusion is on the power correction factor. The reason is that the correction is seen from the engine i...

3 years ago
Reply
RE: Cable from controller to retarder

@osi, it is not normally necessary if you route the power carrying wires away from the signal wires and the instrument unit.

3 years ago
Reply
RE: Cable from controller to retarder

From the controller to the power supply you can use any 2 wire cable. It is not carrying current but a digital signal, shielding is not necessary. F...

3 years ago
Reply
RE: AFR vs Lambda

Hey, Yes for sure! You can program the Aux channels to show anything, the default is just an example. Type in the Sensor type and Unit (if any) and ...

3 years ago
Reply
RE: Latest software version

@matteozanusso, send the exact error message to me at jostein@yourdyno.com if it happens again. Exit YourDyno before upgrading.

3 years ago