Jostein
@admin
Admin
Member
Topics: 26 / Replies: 1360
Reply
RE: Software/firmware updating from old version

All the can bus configurations are stored here: C:\ProgramData\YourDynoPlugins\ControlCAN.dll.json Settings for the old version are preserved when u...

2 months ago
Reply
RE: ultimate firmware

You mean the water brake valve zero position sensor? It can be connected to RPM2, 3 or 4 if Freq 1 and 2 are used.

2 months ago
Reply
RE: Water/Oil temperature thermistor setup

Hi, Open the box, move the pullup jumper.

2 months ago
Reply
RE: Latest software version

Hi folks, A new minor release 3.3.74 (beta) with a few cleanups/changes: Support for 2 water brake valves that move in parallel. This is used f...

2 months ago
Reply
RE: ultimate dyno software setup

There are manuals onbut not a step by step guide as there are so many different dyno types and engine types. We can login and help you set it up th...

2 months ago
Reply
RE: ultimate firmware

OK, disconnect and connect power again. If you have connection again then click "Jump to bootloader". If that does not work, then your usb extension...

2 months ago
Reply
RE: ultimate firmware

Does the download start? What is the error message?

2 months ago
Reply
RE: can bus

That can be used as information to define the channels. Let me know if you need any help and i can do it. Message me directly on Whatsapp: +47 4840 12...

2 months ago
Reply
RE: can bus

Hi, By far the easiest way is to ask EcuMaster for the CAN bus .dbc file. This can be read into YourDyno, and all channels are automatically configu...

2 months ago
Reply
RE: Different HP readings small engine

Hi, this is likely because the Moment of Inertia is wrong. With different gearing, the acceleration on the brake is different. You will likely see the...

3 months ago
Reply
RE: Best retarder for a dynojet 150 motorcycle dyno?

All the well-known brands are good, Telma, Frenelsa, Klam etc. The KAS series from Keao Retarder in China is apparently not fully at the same level, b...

3 months ago
Reply
RE: sf901

That's a flow meter, right? There are a few different types. Do you have the spec for it? If this is a FloScan, then it needs 12V and the signal conne...

3 months ago
Reply
RE: 4.5 volt output load cell

No, amplified load cells with 0-5V output cannot be used as the regular YourDyno load cell. You can likely remove the load cell amplifier though so yo...

3 months ago
Reply
RE: Best way to monitor wheel spin / slip

Hi, The best way is to read the real engine RPM either via RPM pickup or CAN bus (OBD2 is too slow) and then create a math channel called Slip which...

3 months ago
Reply
RE: RPM From Canbus

I don't understand fully. Give me a call on +47 4840 1279 (whatsapp or phone) and I will take a look. Install Ultraviewer first so I can login to your...