RE: Superflow 883 AWD.. more questions

Yes, the best is to use different profiles for the different modes. If you disable an RPM sensor (set it to Not Used), then this wheel pair is ignored...

4 months ago
Reply
RE: Latest software version

@trevor-briggs yes, just turn the monitor vertically and split the screen. This is setup by Windows, the graph and gauge windows can be arranged as yo...

4 months ago
Reply
RE: Latest software version

@trevor-briggs If you have a Standard v5 without CAN bus license, then the licence can be bought in the web shop ($250).

4 months ago
Reply
RE: Superflow 883 AWD.. more questions

Hi, Nice dyno. The brake is the master. So number of pulses per brake revolution is what we are after. So if the trigger wheel is on the brake ax...

4 months ago
Reply
RE: Unused load cell input usage

Yes, you can do that. In the latest software version, all Load cell torque channels are available. You need a math channel to convert from torque to...

4 months ago
Reply
RE: Dyno Testing Side By aside with CVT Transmission

Hi, You can create a results graph tab with Speed as the X-axis and do a Power sweep vs speed. In theory you could also use variable gear ratio a...

4 months ago
Reply
RE: negative calibration weight?

You can calibrate using the normal method (i.e. positive numbers). When you are done, click Reverse calibration.

4 months ago
Reply
RE: Latest software version

@trevor-briggs yes, HalTech WB01 controllers are supported. Select the Haltech Wideband in the drop down in the CAN input setup. Note that you need a ...

4 months ago
Reply
RE: Latest software version

Folks, UnaVision 4.0.42 (beta) was released today. Changes: Fix of Load settings functionality Alternating colors in the Results table for ea...

4 months ago
Reply
RE: Old Software Settings Not Loading

Yes, you are right. This functionality is broken in version 4.0.41. Version 4.42 comes out now. Thanks for reporting.

4 months ago
Reply
RE: Load Cell sensitivity

Hi, The inputs are made for 2mV/V.

4 months ago
Reply
RE: Latest software version

Yes, they can run in parallel. If you see any issues, you may need to run the V3 installer again after installing UnaVision and click Repair. Only one...

4 months ago
Reply
RE: Latest software version

Folks, UnaVision 4.0.41 (beta) was released today. Changes: Ability to set the database folder. See Options->Dyno Type and profiles Bette...

4 months ago
Reply
RE: Latest software version

@hansl to copy the CANTool settings from the old program, exit YourDyno/Unavision and copy C:\ProgramData\YourDynoPlugins\ControlCAN.dll.json to C:\Pr...

4 months ago
Reply
RE: Latest software version

@doctor-542 that is a good idea, and should work well. I will put it on the to-do list.