Q&A Forum

Jostein Fonneland
@cmadmin
Admin
Member
Topics: 2 / Replies: 81
Reply
RE: Latest software version

@hansl to copy the CANTool settings from the old program, exit YourDyno/Unavision and copy C:\ProgramData\YourDynoPlugins\ControlCAN.dll.json to C:\Pr...

3 weeks ago
Reply
RE: Latest software version

@doctor-542 that is a good idea, and should work well. I will put it on the to-do list.

3 weeks ago
Reply
RE: Chassis dynamometer speed sensor tooth count

About 30 teeth is good. Anything from 20 to 100 is ok.

3 weeks ago
Reply
RE: Display PAD

That looks awesome, thank you! I will order one and try it out.

3 weeks ago
Reply
RE: Latest software version

@dev no, the database location is not editable yet. It is underway

3 weeks ago
Reply
RE: Latest software version

Hi folks, UnaVision version 4.0.39 was released today (Beta). Changes: More colors in the database table Ability to show any column that is in ...

3 weeks ago
Reply
RE: RPM sensor issue

OK, so the sensor is not strong enough. Send the signal through this board: SparkFun Opto-isolator Breakout - SparkFun Electronics

4 weeks ago
Reply
RE: RPM sensor issue

Hi, The RPM signal input has a pullup of 500 ohm so the sensor needs to be able to pull the signal down to close to 0V. If the sensor is not strong ...

4 weeks ago
Reply
RE: Latest software version

Folks, UnaVision 4.0.36 was just released (Beta). A few fixes: Channel averaging was always turned on for all channels, even though only Powe...

1 month ago
Reply
RE: Latest software version

@dev I just tested what you described and cannot reproduce the problem. I can login to your PC and see if I understand what you mean. Contact me direc...

1 month ago
Reply
RE: Latest software version

@trevor-briggs on the options import: Yes, on the old YourDyno program, do an Options->Backup options to file, and in UnaVision do a Options->Dy...

1 month ago
Reply
RE: Latest software version

@bendd regarding cropping. You cannot undo a crop on imported runs by right clicking, because of the file format. However, crops are not stored either...

1 month ago
Reply
RE: Latest software version

@max-irvin check the RPM settings in Options->RPM and Frequency channels. If you cannot figure it out, send a copy of the settings to jostein@yourd...

1 month ago
Reply
RE: Latest software version

@hansl the plugins are now here: c:\ProgramData\UnaVisionPlugins. Put the CANTool config there. For the PTH200 you need to enter the folder location f...

1 month ago
Reply
RE: Latest software version

Hi folks, Another quick update, version 4.0.33. Fix: Printing bug Note: If you experience slow loading of runs from the database, turn off Avera...

1 month ago